logo
Found 90 products for "

dynamical system cable

"
Chất lượng Đầu dò nội soi Ultrasonix EC9-5/10 để sửa chữa nhà máy

Đầu dò nội soi Ultrasonix EC9-5/10 để sửa chữa

Ultrasonix EC9-5/10 Endo-cavitary probe for repair ► Brief Description Fault: Bad array element. Solution: Replace crystal and housing. ►Problem & Solutoin BrandUltrasonix ModelEC9-5/10FaultBad array elementSolutionReplace crystal and housing ► Common issues with EC9-5/10 Probe Image Dropouts or Streaks (Dead Elements)Acoustic Lens DamageCable and Strain Relief DamageHousing or Casing Damage ►FAQHow can I tell if my EC9-5/10 has a crystal failure or a cable failure?Crystal

Chất lượng Richard Wolf 85525922 ENDOCAM Logic HD 3 chip đầu máy ảnh nhà máy

Richard Wolf 85525922 ENDOCAM Logic HD 3 chip đầu máy ảnh

Richard Wolf 85525922 ENDOCAM Logic HD 3-Chip Camera Head ► Brief Description The Richard Wolf 85525922 is a professional-grade ENDOCAM Logic HD 3-Chip Camera Head. It is designed for high-end endoscopic imaging, offering superior color reproduction and clarity through its triple-sensor technology.It is a high-performance imaging component designed for minimally invasive surgery ,used in various surgical disciplines (Laparoscopy, Arthroscopy, etc.) to provide high-definition

Chất lượng Phần mềm Endoscope linh hoạt CCD bảng điều khiển cho PENTAX EC-3890LK Colonoscope nhà máy

Phần mềm Endoscope linh hoạt CCD bảng điều khiển cho PENTAX EC-3890LK Colonoscope

CCD Driver Board For PENTAX EC-3890LK Colonoscope ► Brief Description The CCD Driver Board for the PENTAX EC-3890LK is a critical internal electronic component located within the video colonoscope. Its primary role is to drive the Charge-Coupled Device (CCD) image sensor located at the distal tip of the endoscope. It manages the precise timing signals required to capture high-resolution medical images and prepares the raw video data for transmission back to the main PENTAX

Chất lượng Olympus CCD cho BF-260 Bronchoscope cho các thủ tục y tế nhà máy

Olympus CCD cho BF-260 Bronchoscope cho các thủ tục y tế

Olympus CCD for BF-260 Bronchoscope Spare parts of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF-XQ260,

Chất lượng Olympus CCD cho GIF-XQ260 Gastroscope với CCD Series nhà máy

Olympus CCD cho GIF-XQ260 Gastroscope với CCD Series

Olypmus CCD for GIF-XQ260 Gastroscope Spare parte of Olympus Spare parts for BF-P290, GIF-XP290, GIF-H290Z, CF-HQ290ZI, PCF-HQ290ZI, CF-HQ290I, JF-260V, CF-V70I, CF-H260AZI, GIF-V70, GIF-H260, GIF-LV1, BF-IT260, BF-260, BF-F260, BF-IT60, BF-XP260F, BF-P260F, ENF-V2, LTF-3D, CYF-VA2, CHF-V, BF-1TQ290, CYF-VHA, ENF-VH, CYF-VA2, LTF-190-10-3D, CF-H170, GIF-H170, GIF-H290, CF-H290I, CF-HQ290I, URF-V, URF-V2, ENF-V3, GIF-HQ290, BF-1T260, URF-V, PCF-H290DI, LTF-S190-10-3D, GIF

Chất lượng Điện tử mảng tuyến tính cho tàu thăm dò L12-5 nhà máy

Điện tử mảng tuyến tính cho tàu thăm dò L12-5

Array element for L12-5 probe ► Brief Description The L12-5 probe is a sophisticated linear array ultrasound transducer renowned for its versatility in high-resolution imaging. Its core functionality hinges on its array elements. ► Features Ultrasound Generation: Each element is capable of converting electrical energy into mechanical (ultrasound) vibrations. When an electrical pulse is applied, the element vibrates and generates a short burst of ultrasound waves. Echo

Chất lượng Bộ chuyển đổi dây đèn góc vuông 90 độ cho bó dẫn sáng Karl Storz nhà máy

Bộ chuyển đổi dây đèn góc vuông 90 độ cho bó dẫn sáng Karl Storz

Right Angle 90 degree Light Cord Adaptor For Karl Storz Light Guide Bundle ► Brief Description The Karl Storz Light Guide Bundle Adaptor is an accessory used in endoscopic and surgical lighting systems to connect light cables (light guides) to light sources or other optical components. Karl Storz is a leading manufacturer of medical and surgical equipment, particularly known for its high-quality endoscopes and illumination systems. ► Features Compatibility – Designed to work

Chất lượng S5-1 Sonde siêu âm cho sửa chữa nhà máy

S5-1 Sonde siêu âm cho sửa chữa

S5-1 sector array ultrasound probe for repair ► Brief Description Fault: Array element aging, lens bubble. Solution: Replace Crystal. ►Problem & Solutoin ModelS5-1FaultArray element aging, lens bubbleSolutionReplace Crystal ► Common issues with S5-1 Probe Image Dropouts / Dead ElementsAcoustic Lens DamageCable DamageConnector DamageWeak or Noisy Image ►FAQ What causes "dark shadows" or vertical dropouts on the S5-1 screen, and can it be fixed? A: Vertical black lines or blind

Chất lượng Olympus MAJ-1121 Tay dò nhà máy

Olympus MAJ-1121 Tay dò

Olympus MAJ-1121 Transducer Handpiece ► Brief Description The MAJ-1121 is a dedicated Remote Signal Cable designed for medical endoscopy systems. It serves as the communication bridge between the Olympus Video Processor and peripheral imaging devices. ► Features Signal Transmission: It relays trigger signals from the remote switches (buttons) located on the endoscope handle to external equipment.Workflow Integration: Enables the endoscopist to control capturing, printing, or

Previous
Page 7 của 10
Next