Chất lượng M1941A Cáp mở rộng SpO2 cho máy theo dõi bệnh nhân nhà máy

M1941A Cáp mở rộng SpO2 cho máy theo dõi bệnh nhân

M1941A SpO2 Extension Cable For Patient Monitors ► Brief Description The M1941A (often referred to as the M1941A SpO2 Adapter Cable) is a medical-grade extension cable designed to connect patient monitors with compatible SpO2 (pulse oximetry) sensors. It acts as a crucial intermediary link, ensuring accurate, real-time transmission of oxygen saturation and pulse rate data from the patient to the monitoring system. ► Features Stable Signal Transmission Plug-and-Play Compatibil

Chất lượng Anschlusskabel Flow Sensor Drager (93) 8416600-13 Đối với máy thông gió dòng Evita / Savina nhà máy

Anschlusskabel Flow Sensor Drager (93) 8416600-13 Đối với máy thông gió dòng Evita / Savina

Anschlusskabel Flowsensor Drager (93)8416600-13 For Evita Series/Savina Ventilators ► Brief Description For the Drager (93)8416600-13 (often cross-referenced with P/N 8411794), this is the specialized interface cable used to connect the flow sensor to the ventilation unit. ►Features Signal Transmission Power Supply Plug-and-Play (Self-Locking) EMI Shielding Hot-Wire Anemometry Support Flexible Deployment ► Specification Brand Drager Part Number (93)8416600-13 Condition

Chất lượng Công cụ sửa chữa cho Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd nhà máy

Công cụ sửa chữa cho Olympus Otv-S7proh-Hd-12 Otv-S7proh-Hd-12e Q Otv-S7proh-Hd

REPAIR TOOLS FOR OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD CABLE Brand: OLYMPUS Model: OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD Condition: Brand new A repair tool that can be used to repair OLYMPUS OTV-S7ProH-HD-12 OTV-S7PROH-HD-12E/Q OTV-S7PROH-HD cable. It can be securely fixed and easy to repair cable. We provide trading and service of Ultrasound unit/Transducer, Dynamic system device/parts, Rigid endoscope parts and Flexible endoscope parts, we

Chất lượng Đầu camera OLYMPUS OTV-S6H-1D để sửa chữa nhà máy

Đầu camera OLYMPUS OTV-S6H-1D để sửa chữa

Olympus OTV-S6H-1D Camera Head For Repair ► Brief Description Fault: 1.Image yes. 2.Cable aging and interference Solution: Replace new cable. ►Problem & Solutoin Brand Olympus Model OTV-S6H-1D Fault Cable aging and interference Solution Replace cable ► Applications Laparoscopy (abdominal surgery) Arthroscopy (joint surgery) ENT (Ear, Nose, Throat) procedures General endoscopic imaging ► Troubleshooting & Support If the camera is not functioning, check: Cable connections

Chất lượng C5-2 Máy thăm dò cong để sửa chữa các bộ phận thiết bị y tế nhà máy

C5-2 Máy thăm dò cong để sửa chữa các bộ phận thiết bị y tế

C5-2 Convex Probe For Repair ► Brief Description Fault: Strain relief damage, cable broken. Solution: Replace strain relief, repair cable. ►Problem & Solutoin Model C5-2 Convex Fault Strain relief damage, cable broken Solution Replace strain relief, repair cable ► Common Issues with C5-2 Probes Dead or flickering elements (image dropouts, black lines) Cable damage (broken wires near the connector or handle) Lens damage (cracks, delamination, or wear) Acoustic array failure

Chất lượng Đầu dò siêu âm robot BK Medical 9096 để sửa chữa nhà máy

Đầu dò siêu âm robot BK Medical 9096 để sửa chữa

BK Medical 9096 Robotic Ultrasound Probe For Repair ► Brief Description Fault: All the outer skin of the cable is seriously damaged. Solution: Replace the outer skin of the cable. ►Problem & Solutoin Brand BK Medical Model 9096 Fault All the outer skin of the cable is seriously damaged Solution Replace the outer skin of the cable ► Common issues with 9096 Probes Cable Damage Acoustic Lens/Membrane Damage Probe Housing Damage Crystal Array Damage Robotic Grasping Interface

Chất lượng Stryker 1188-210-105 đầu máy ảnh để sửa chữa nhà máy

Stryker 1188-210-105 đầu máy ảnh để sửa chữa

STRYKER 1188-210-105 camera head for repair ► Brief Description Fault: Image with interrupt. Cable aging. Solution: Replace compatible new cable and connector. ►Problem & Solutoin Brand STRYKER Model 1188-210-105 Fault Image with interrupt. Cable aging Solution Replace compatible new cable and connector ► Common issues with 1188-210-105 camera head Image Quality Problems Physical and Cable Damage Button and Control Malfunctions Overheating If your instrument has any of the

Chất lượng GE 4C-RS thăm dò bụng để sửa chữa nhà máy

GE 4C-RS thăm dò bụng để sửa chữa

GE 4C-RS abdominal probe for repair ► Brief Description Fault: Lens broken, cable broken, crystal bad. Solution: Replace probe head, repair cable. ►Problem & Solutoin Bran GE Model 4C-RS Fault Lens broken, cable broken, crystal bad Solution Replace probe head, repair cable ► Common issues with 4C-RS Probe Image dropouts / Black lines Acoustic lens damage Cable damage Connector damage Oil leakage If your instrument has any of the above problems or others, please feel free to

Chất lượng S5-2 Đầu dò tim mạch để sửa chữa nhà máy

S5-2 Đầu dò tim mạch để sửa chữa

S5-2 Cardiac probe for repair Fault: Lens problem, cable broken, without strain relief. Solution: Replace probe lens, repair cable, replace strain relief. ►Problem & Solutoin Model S5-2 Fault Lens problem, cable broken, without strain relief Solution Replace probe lens, repair cable, replace strain relief ► Common issues with S5-2 Cardiac probe Poor or blurry images Constant noise or static Color streaking or intermittent artifacts Cracked or dried-out lens Cable or strain